VEOLIA 2020 EDR systems

VEOLIA 2020 EDR systems

VEOLIA 2020 EDR

systems

The veolia 2020 Electrodialysis Reversal (EDR) product is a proven and reliable desalination technology that has been in service in a variety of industrial and public infrastructure applications.

electrodialysis reversal technology

EDR features

  • Use of Carbon Electrodes results in no gas pro- duced and no separate electrode stream required.
  • High Water Recovery, up to 94%
  • Salt Removal of 50 to 95%
  • Polarity Reversal self-cleaning with electricity
  • Free chlorine tolerance
  • Tolerance to moderate suspended solids
  • Adjustable product water performance without blending
  • Ability to disassemble stacks for inspection
  • Silica tolerance

EDR benefits

  • Efficient use of scarce water resources
  • Low pretreatment requirements and costs
  • Low chemical consumption costs
  • Long membrane life, typically 10+ years
  • Strong ability to recover from less than ideal feed water quality

standard design and scope of supply

  • MK-IV-2 EDR stacks with veolia Carbon Electrodes
  • Cartridge filter
  • Concentrate Recirculation pump with VFD
  • GE Fanuc1 Micro PLC & 12” (30 cm) color Quick

Panel HMI

  • Full Owners Operation & Maintenance Manual, Factory Acceptance Test results and Stack Per- formance Test results

Water Technologies & Solutions fact sheet

instrumentation – transmitters

Flow Product Outlet, Concentrate Outlet

Pressure Cartridge Filter Inlet & Outlet

Concentrate, Recirculation Pump Outlet, Product Out- let

Conductivity Inlet & Product Outlet

operating parameters

Water Recovery Up to 94%

Salt Removal 50% to 95%

Silica Removal none

Temperature 40 to 100ºF (4 To 38ºC)

Maximum Feed Pressure psi

Input Voltage 480VAC/3/60Hz

feed water requirements

Typical Feed TDS 100 to 3,000 ppm (mg/l)

Maximum Feed TDS 12,000 ppm (mg/l)

Silica (Reactive) unlimited

pH 2 to 10

Find a contact near you by visiting www.veoliawatertechnologies.com and clicking on “Contact Us.”

*Trademark of Veolia; may be registered in one or more countries.

1

GE Fanuc is a trademark of General Electric Company

©2017 Veolia. All rights reserved.

FS1242EN.doc Jul-13

SDI (5 min. test) 10

Turbidity < 0.5 NTU

Free Chlorine (continuous) 0.5 ppm (mg/l)

TOC < 15 ppm (mg/l)

COD < 50 ppm (mg/l) as O2

Iron < 0.3 ppm (mg/l)

Manganese, Aluminum < 0.1 ppm (mg/l)

H2S < 0.1 ppm (mg/l)

allowable intermittent levels:

SDI (5 min. test) 15

Turbidity 2.0 NTU

Free Chlorine 30 mg/l

material of construction

Welded Frame Painted Carbon Steel

Dilute and Concentrate Piping Sch. 80 PVC

Flanges ANSI

Concentrate Pump Single-stage Centrifugal

Rectifier NEMA 3R

Control Panel NEMA 4

quality assurance

Certification UL

Facility SO 9001:2000

EDR 2020 2 & 4 line standard systems

MODEL 2020-2L-2S 2020-2L-3S 2020-4L-2S 2020-4L-3S
Flow Rates
Product Flow Nominal 280 gpm

63.6 m3/h

260 gpm

59.1 m3/h

560 gpm

127.2 m3/h

520 gpm

118.2 m3/h

Product Flow Range 165 to 325 gpm

37.5 to 73.8 m3/h

165 to 270 gpm

37.5 to 61.3 m3/h

325 to 655 gpm

73.8 to 148.8 m3/h

325 to 545 gpm

73.8 to 123.8 m3/h

Concentrate Outlet Flow Depends on recovery and product
Electrode Outlet Flow 2.2 gpm

8.3 lpm

2.5 gpm

9.5 lpm

4.3 gpm

16.3 lpm

5.0 gpm

19 lpm

General Information
Number of Stacks 4 6 8 12
Number of Lines 2 2 4 4
Number of Stages 2 3 2 3
Type of Stack MK-IV-2 MK-IV-2 MK-IV-2 MK-IV-2
Dimensions
System Dimensions Width x Length 90” x 309”

(2.3 x 7.9 m)

90” x 375”

(2.3 x 9.5 m)

169” x 493”

(4.3 x 12.5 m)

169” x 625”

(4.3 x 15.9 m)

Inlet Piping 4” (10 cm) 4” (10 cm) 6” (15 cm) 6” (15 cm)
Product Outlet Piping 4” (10 cm) 4” (10 cm) 6” (15 cm) 6” (15 cm)
Off-Spec Outlet Piping 4” (10 cm) 4” (10 cm) 6” (15 cm) 6” (15 cm)
Electrode Outlet Piping 3” (8 cm) 3” (8 cm) 3” (8 cm) 3” (8 cm)
Concentrate Outlet Piping 1.5” (4 cm) 1.5” (4 cm) 2” (5 cm) 2” (5 CM)
Note: all piping sizes are provided for nominal flow rates at 85% recovery.
Electrical
Maximum Rectifier Output (Per Stack Basis)
Stage 1 590VDC, 46A 590VDC, 26A 590VDC, 46A 590VDC, 26A
Stage 2 518VDC, 18A 518VDC, 14A 518VDC 18A 518VDC, 14A
Stage 3 420VDC, 7.5A 420VDC, 7.5A
Connection Requirement (Includes Feed pump, which may

be supplied by others)

140 KVA 107 KVA 276 KVA 209 KVA
Typical Power consumption 2 – 4 kWh/1,000 gallons of product water
Performance, number of stages and cell pairs, recovery and power consumption are dependent on inlet feed water quality

and temperature. A Watsys projection must be completed by an authorized veolia Water Technologies & Solutions design rep- resentative for proper system design & for any performance guarantee to be provided.

Page 2 FS1242EN.doc

EDR 2020 6 & 8 line standard systems

MODEL 2020-6L-2S 2020-6L-3S 2020-8L-2S 2020-8L-3S
Flow Rates
Product Flow Nominal 840 gpm

190.8 m3/h

780 gpm

177.2 m3/h

1120 gpm

254.4 m3/h

1040 gpm

236.2 m3/h

Product Flow Range 485 to 985 gpm

110.2 to 223.7 m3/h

485 to 820 gpm

110.2 to 186.2 m3/h

645 to 1315 gpm

146.5 to 298.7 m3/h

645 to 1090 gpm

146.5 to 247.6 m3/h

Concentrate Outlet Flow Depends on recovery and product flow rate
Electrode Outlet Flow 6.5 gpm

25 lpm

7.5 gpm

28 lpm

8.7 gpm

33 lpm

10 gpm

38 lpm

General Information
Number of Stacks 12 18 16 24
Number of Lines 6 6 8 8
Number of Stages 2 3 2 3
Type of Stack MK-IV-2 MK-IV-2 MK-IV-2 MK-IV-2
Dimensions
System Dimensions Width x Length 270” x 493”

(6.0 x 12.5 m)

270” x 625”

(6.0 x 15.9 m)

270” x 493”

(6.0 x 12.5 m)

270” x 625”

(6.0 x 15.9 m)

Inlet Piping1 8” (20 cm) 8” (20 cm) 8” (20 cm) 8” (20 cm)
Product Outlet Piping 8” (20 cm) 8” (20 cm) 8” (20 cm) 8” (20 cm)
Off-Spec Outlet Piping 8” (20 cm) 8” (20 cm) 8” (20 cm) 8” (20 cm)
Electrode Outlet Piping 3” (8 cm) 3” (8 cm) 3” (8 cm) 3” (8 cm)
Concentrate Outlet Piping 3” (8 cm) 3” (8 cm) 3” (8 cm) 3” (8 cm)
Note: all piping sizes are provided for nominal flow rates at 85% recovery.
Electrical
Maximum Rectifier Output (Per Stack Basis)
Stage 1 590VDC, 46A 590VDC, 26A 590VDC, 46A 590VDC, 26A
Stage 2 518VDC, 18A 518VDC, 14A 518VDC 18A 518VDC, 14A
Stage 3 420VDC, 7.5A 420VDC, 7.5A
Connection Requirement (Includes Feed pump, which may

be supplied by others)

380 KVA 285 KVA 542 KVA 397 KVA
Typical Power consumption 2 – 4 kWh/1,000 gallons of product water
Performance, number of stages and cell pairs, recovery and power consumption are dependent on inlet feed water quality

and temperature. A Watsys projection must be completed by an authorized veolia Water Technologies & Solutions design rep- resentative for proper system design & for any performance guarantee to be provided.

FS1242EN.doc Page 3

Hemen Ara
Navigasyon